ZEKTORSerial Optionwww.zektor.com400-000006-08 (Rev 8) 4/19/05 TMZ-SLOTRS-232 Serial Port Option
10
11The HDS4.2Serial OptionZEKTORTM
12The HDS4.2 Command SetPower ControlP0<CR> Turn off powerP1<CR> Turn on powerP+<CR> Toggle powerP?<CR> Request power statusBu
13Set Front Panel IntensitiesI<min><space><max> Set the minimum and maximum front panel intensities.Where:<min> = The minumum
14Save Current State As Power On DefaultS<CR> Save HDS4.2’s current state as the power on defaultRequest VersionV<CR> Request the HDS4.2’s
15The HDS4.2 Response StringsThe section list the strings returned from the HDS4.2.All HDS4.2 strings are terminated with the characters <CR><
16Button Press=B<button><CR><LF><button> = A one digit ASCII value that indicates the last button pressed on the front panel.1
17
18The DVS5.1Serial OptionZEKTORTM
19The DVS5.1 Command SetPower ControlP0<CR> Turn off powerP1<CR> Turn on powerP+<CR> Toggle powerP?<CR> Request power statusBu
2Copyright © 2005 Zektor, LLC. All rights reserved.
20Set Front Panel Lamp ModeL0<CR> Set lamps to the dim settingL1<CR> Set lamps to the bright settingL2<CR> Set lamps to the auto-dim
21Control BitsX<ControlBits>0<CR>Where:ControlBits = Status control bits. This is a bitmapped value, given in decimal.0 Reserved, always s
22The DVS5.1 Response StringsThe section list the strings returned from the DVS5.1.All DVS5.1 strings are terminated with the characters <CR><
23Button Press=B<button><CR><LF><button> = A one digit ASCII value that indicates the last button pressed on the front panel.1
24Customer Service contact information:ZEKTOR, LLC12675 Danielson CourtSuite 401Poway, CA 92064Phone: 858-748-8250Email: [email protected]
3An RS-232 OverviewThe RS-232 interface for Zektor products has been designed to be simple, straight forward and still allow the installer full access
4Where:+ = The ‘+’ character.<CR><LF> = The Carriage Return and Line feed characters.Every command that does not cause an error will be r
5The MAS3Serial OptionZEKTORTM
6The MAS3 Command SetPower ControlP0<CR> Turn off powerP1<CR> Turn on powerP+<CR> Toggle powerP?<CR> Request power statusSelec
7Auto Status ControlX0<CR> Turn off auto-status transmissionsX1<CR> Turn on auto-status transmissionsX?<CR> Request current auto sta
8The MAS3 Response StringsThe section list the strings returned from the MAS3.All MAS3 strings are terminated with the characters <CR><LF>
92 - Automatic bright to dim setting.Query Command Status String=Q<pending><CR><LF> Return buffered status state of the MAS3<pend